In most housing societies and many factories, water still depends on a person: someone climbs to the terrace to check the overhead tank, someone switches the pump on, and someone is supposed to switch it off before the tank overflows. When that person is late, sick or busy, tanks overflow, pumps run dry and burn out, or a building runs out of water at 7 am.
Tank level sensors and pump controllers connected over LoRa remove that dependence. This guide explains how such a system works, why LoRa suits it, and what to ask for before you buy.
The problems it solves
| Problem | What happens | What automation does |
|---|---|---|
| Overflow | Water and electricity wasted, wet terraces and walls | Stops the pump when the overhead tank is full |
| Dry running | Pump runs with no water in the sump and is damaged | Stops or blocks the pump when the sump is low |
| Empty tanks | Residents or production lines run out of water | Starts the pump in time, and alerts if it can't |
| Manual rounds | Staff time, and the system fails when someone forgets | Levels are visible on a phone or a screen |
| No records | Disputes about supply, no idea of daily use | Daily consumption and pump run hours are logged |
How the system works
- Level sensors on each tank and sump measure the water level, usually with an ultrasonic sensor mounted on top of the tank or a pressure sensor at the bottom.
- LoRa radios send the readings to a gateway. One gateway can usually cover a building complex or a factory site, depending on the layout.
- A pump controller near each pump starts and stops it, based on rules: fill the overhead tank between set levels, but only if the sump has enough water.
- Software shows the levels, pump status and alerts on a phone and a dashboard, and keeps daily records.
The rules run close to the pump, so the system keeps protecting the pump even if the internet connection drops.
Why LoRa suits water systems
Tanks are often far apart: overhead tanks on several buildings, an underground sump near the gate, a borewell at the corner of the plot. Running cables between them is expensive and messy. Wi-Fi rarely reaches terraces and basements reliably.
LoRa (and the LoRaWAN network standard built on it) is designed for exactly this kind of job: small readings sent every few minutes over long distances at very low power, so sensors can run on batteries. In India, LoRaWAN uses the 865–867 MHz band (The Things Network frequency plans), which is licence-exempt for low-power devices. Our connectivity guide compares LoRaWAN with Wi-Fi, NB-IoT and 4G and covers the radio approval rules.
Housing societies and factories: what's different
Housing societies usually want:
- Automatic filling of overhead tanks from the sump, with dry-run protection
- Level alerts on the committee's and the caretaker's phones
- A record of water tanker deliveries and municipal supply hours
- Simple, robust hardware that a local electrician can maintain
Factories usually also want:
- Monitoring of process water, cooling towers and fire-water tanks (where a low level is a safety issue)
- Flow meters to measure consumption by area or line
- Data for reporting water use, which large customers increasingly ask for (see BRSR Core energy and water data)
- Integration with existing building or plant systems
What to ask before you buy
- Sensor type and mounting: is it suitable for your tank (open or closed, depth, inlet turbulence)?
- Dry-run protection: does the controller check the sump before starting the pump?
- Behaviour without internet: do the pump rules keep working locally?
- Battery life and replacement: how long do sensor batteries last at your reporting interval, and who replaces them?
- Manual override: can staff still run the pump by hand in an emergency?
- Alerts: who gets them, and how (app, SMS, WhatsApp)?
- Electrical safety: is the pump controller installed in a proper panel by a licensed electrician?
- Data ownership: can you export your records?
- Security: are devices and the app protected properly? Our IoT security checklist lists what to check.
A simple rollout
- Survey: list every tank, sump, borewell and pump, with distances and power availability.
- Start with the biggest problem: usually the overhead tanks that overflow or the pump that has burned out before.
- Install sensors and one gateway, check radio coverage to every tank, then add pump controllers.
- Run in "monitor only" mode for a week, so staff can see the levels before automation takes over.
- Switch on automation and alerts, with manual override kept in place.
Frequently asked questions
How does a water level monitoring system for a society work?
Sensors on each tank measure the level and send it over a radio link (such as LoRa) to a gateway. A controller starts and stops the pumps based on the levels, and the committee sees everything on a phone app.
Can it stop the pump from running dry?
Yes. The controller checks the sump level before starting the pump and stops it if the level drops too low.
What happens if the internet goes down?
In a well-designed system, the pump rules run locally, so tanks keep filling safely. Alerts and the app resume when the connection returns.
Why LoRa instead of Wi-Fi?
LoRa reaches across buildings, terraces and basements with low power, so sensors can run on batteries without new cabling. Wi-Fi rarely covers all tank locations reliably.
Can this work with our existing pumps?
Usually yes. The controller switches the existing pump starter. An electrician checks the panel during the survey.
Tired of overflowing tanks and burned-out pumps? Send us the number of tanks, sumps and pumps on your site and a rough layout. We'll suggest the sensors, controllers and gateway placement. Explore IoT development → · Talk to us →