Most factories look at one number on the electricity bill: the total. But an Indian industrial bill is built from several parts, and some of them depend less on how much energy you use than on when and how you use it. A short spike in load, a few capacitors that have failed, or a furnace that starts at 6 pm instead of 2 pm can each add to the bill without producing anything extra.
This guide explains the parts of the bill that monitoring can reduce, with the rules that apply in India today and Maharashtra as a worked example. It's written for plant heads and energy managers, not electrical engineers.
The four parts of the bill you can influence
| Part of the bill | What it charges for | What drives it |
|---|---|---|
| Demand (fixed) charge | Your maximum demand in kVA, per month | The highest load drawn in a short interval during the month |
| Energy charge | Units consumed (kWh, or kVAh where kVAh billing applies) | How much you run, and your power factor under kVAh billing |
| Time-of-day (ToD) charge or rebate | When you consume | Shifting load into cheaper hours and out of the evening peak |
| Penalties | Exceeding contract demand, and other tariff conditions | Load spikes, unplanned starts |
Your state's tariff order sets the exact rules and rates. Always check them on your own bill and your distribution company's current tariff schedule.
1. Maximum demand: one bad interval can set the whole month
Demand charges are based on the highest load your factory draws during the month, measured by the meter over a short interval, typically 15 or 30 minutes depending on the meter and the tariff. One interval in which several large motors, compressors and furnaces start together can set the demand figure for the whole month.
Many tariffs also set a minimum billing demand as a percentage of your contract demand, and charge extra if you go above the contract demand. Check both rules in your tariff schedule.
What monitoring does:
- Shows the demand curve every few minutes, so you can see which loads create the peak
- Alerts the shift supervisor when demand approaches a limit you set, before the interval closes
- Supports simple rules: stagger the start of large motors, delay non-urgent loads, or switch off a load automatically when demand is close to the limit
The data you need: a meter at the incomer that reports kVA demand, and sub-meters on the largest loads (compressors, furnaces, chillers, large motors).
2. Power factor under kVAh billing
Under kWh billing, a poor power factor was handled through separate incentives and penalties. Under kVAh billing, it's built into the units themselves: the meter counts apparent energy (kVAh), which is higher than real energy (kWh) whenever the power factor is below 1. So the same work costs more units.
kVAh billing is now common for industrial consumers. In Maharashtra, for example, the energy charge for HT industry is set in rupees per kVAh, and MERC's 2025 tariff order extended kVAh billing to LT consumers with a load of more than 20 kW (MERC press note, March 2025).
What monitoring does:
- Tracks power factor continuously, at the incomer and on large loads
- Alerts when it drops, which often means a capacitor bank has failed or a stage isn't switching in
- Shows the cost of the drop in rupees, so the repair gets priority
3. Time-of-day tariff: when you run matters
The Government of India's Electricity (Rights of Consumers) Amendment Rules, 2023 require time-of-day tariffs for commercial and industrial consumers with a maximum demand of more than 10 kW from 1 April 2024 at the latest, and for most other consumers (except agricultural) from 1 April 2025 (Power Line, June 2023). The aim is to make power cheaper during solar hours and dearer at the evening peak.
Maharashtra example. MERC's multi-year tariff order for MSEDCL (Case No. 75 of 2025) defines solar hours as 9 am to 5 pm and the evening peak as 5 pm to midnight (MERC press note). For FY 2025-26, industrial and commercial consumers get a rebate on the energy charge during solar hours (15% from April to September and 25% from October to March) and pay 25% more during the evening peak. The modified order removed the earlier night-time rebate (summary of the modified order). The order has been revised more than once, so check the current figures in the latest order or on your bill.
What monitoring does:
- Splits consumption by ToD slot, by line and by machine, so you know what runs in the peak
- Finds loads that could move: water pumping, compressed-air storage, batch processes, cold-store pre-cooling, EV charging, cleaning shifts
- Tracks the saving after each change, in rupees, using the ToD rates on your bill
4. Energy per unit of output
Once the bill's controllable parts are handled, the next step is energy per unit of production: kWh per tonne, per part or per batch. This shows waste that the monthly bill hides: compressors running on leaks during breaks, machines idling between jobs, or one line using more energy than an identical one. Linking energy data to production counts is the same work as OEE monitoring, and it's the basis for the energy figures customers increasingly ask suppliers for (see BRSR Core energy and water data).
What a factory energy monitoring setup includes
| Part | What it is |
|---|---|
| Meters | A main meter at the incomer (or a connection to the utility meter's data port, where allowed), plus sub-meters on large loads and on each line |
| Gateway | Reads meters over Modbus and sends data every minute or few minutes. Most modern energy meters already support Modbus. See connecting meters with Modbus |
| Software | Live demand and power factor, ToD split, alerts, monthly reports, energy per unit of output |
| Actions | Alerts to the supervisor, and where it's safe, automatic switching of non-critical loads |
For three-phase loads that need both monitoring and remote switching, a 3-phase smart switch can do both. Commercial buildings have similar problems with different loads. See energy management for commercial buildings.
A 30-day plan to find the first savings
- Week 1: Collect 12 months of electricity bills. Note maximum demand, power factor (or kVAh against kWh), and ToD consumption for each month.
- Week 1–2: Install or connect meters at the incomer and on the 5–10 largest loads.
- Week 2–3: Look at the demand curve. Find the intervals that set the monthly maximum and which loads were running.
- Week 3: Check power factor by load. Inspect capacitor banks where it drops.
- Week 4: List loads that could run in solar hours instead of the evening peak. Agree changes with production.
- After that: Turn on alerts for demand and power factor, and track the saving monthly against the bill.
Frequently asked questions
What is maximum demand on an electricity bill?
The highest load your connection drew in any short metering interval during the month, measured in kVA. Demand charges are calculated from it, so one spike can raise the whole month's bill.
Why does power factor matter under kVAh billing?
Because the meter bills apparent energy (kVAh). A lower power factor means more kVAh for the same useful work, so you pay for more units.
Which industries benefit most from the time-of-day tariff?
Those with loads that can move in time: water pumping, compressed air with storage, cold storage, batch processes and EV charging.
Can monitoring work with our existing meters?
Often yes. Most modern energy meters have a Modbus port. A gateway can read them without replacing them.
Do we need to change our tariff or connection?
No. Monitoring helps you use your existing tariff better. If your contract demand is far above what you actually use, the data also helps you discuss a revision with your distribution company.
Want to see where your electricity bill can come down? Send us 12 months of bills and a list of your largest loads. We'll show you which parts of the bill monitoring can reduce, and what to meter first. Explore energy and utilities IoT → · Talk to us →