An industrial IoT project isn't one piece of software. It's a sensor bolted to a machine, firmware running on a small processor, a radio link across a noisy shop floor, a cloud platform, a dashboard, and usually a link into your ERP or maintenance system. If any one of those links is weak, the whole project fails, and you'll usually find out months after the contract is signed.
That's why choosing an IoT partner is harder than choosing a web or app developer. You're not buying a website you can redesign next year. You're buying devices that will sit in your plant for five to ten years and need updating, securing and supporting all that time.
This guide gives you 15 questions to ask every vendor on your shortlist, what a good answer sounds like, and the red flags that should end the conversation.
First, know what you're buying
Before comparing vendors, list the layers your project needs and ask each vendor which layers they build themselves and which they buy in or subcontract.
| Layer | What it is | Typical owner |
|---|---|---|
| Sensors and devices | Current clamps, vibration, temperature, level, energy meters, or a custom board | Vendor, a hardware partner, or off-the-shelf |
| Firmware | Code on the device: reading sensors, saving data when offline, updates | Vendor (if custom hardware) |
| Connectivity | Wi-Fi, LoRaWAN, NB-IoT, 4G, Ethernet, RS-485 | Vendor design, telecom provider for SIMs |
| Gateway or edge | Box on site that collects readings, converts protocols and buffers data | Vendor or off-the-shelf |
| Cloud platform | Device registry, data storage, rules and alerts | Vendor platform, AWS IoT, Azure, or custom |
| Dashboards and apps | What your team actually looks at | Vendor |
| Integration | ERP, maintenance (CMMS), MES or BI tools | Vendor + your IT team |
| Installation and support | Site survey, wiring, commissioning, ongoing fixes | Vendor or local partner |
A vendor doesn't have to build every layer. But someone must own the whole chain, and you need to know who.
The 15 questions
A. Proof: can they show it, not just describe it?
1. Can you show me a live system, not slides? Ask to see a working dashboard with real or realistic data moving through it, and a device you can hold. A good vendor can open a demo in the meeting. Slides and stock photos of factories are not proof.
2. Which parts of that demo did your own team build? Many "IoT companies" resell a platform and add a logo. That can be fine, but then you depend on that platform's pricing and roadmap. Ask for the split: hardware, firmware, cloud, apps.
3. Can we speak to a client whose project is in production, not in pilot? Pilots are easy. Running 300 devices for two years is hard. If references aren't possible under NDA, ask for an anonymised description of a live deployment: number of devices, how long it has run, what went wrong and how it was fixed.
B. Engineering depth: will it work in your plant?
4. How will you get data from our existing machines? Most plants have a mix of old and new equipment. A strong answer covers reading PLCs and meters over Modbus or OPC UA, adding sensors where there's no controller, and how they'll handle different makes. Weak answers assume you'll replace hardware. (See our guide to retrofitting old machines and PLCs.)
5. What happens when the network goes down? Shop-floor networks drop. The device or gateway should store readings and send them later, with the correct timestamps, rather than leaving gaps. Ask how many hours of data it can hold.
6. How do you update firmware on devices already installed, and how do you roll back a bad update? This is the question that separates engineering teams from integrators. Look for over-the-air (OTA) updates, signed firmware, staged rollout (a few devices first), and a way back if an update fails. If the answer is "we send a technician", multiply that cost by every device and every year.
7. How do you test devices before they leave your office? Ask about power-cycle tests, temperature and humidity exposure, radio range tests in conditions like yours, and long-running "soak" tests. (Our guide to IoT device testing lists what to expect.)
8. How do you decode raw readings, and what happens to a bad reading? Many integration bugs come from decoding: a meter that reads exactly double, or a negative temperature that shows as 6,553.5. A careful vendor will tell you how they handle word order, scaling and signed values, and that a bad or missing reading is dropped and flagged, never guessed or filled with zero. A guessed reading in a maintenance or compliance record is worse than a gap.
C. Security and compliance
9. How is each device identified and authenticated? Each device should have its own credentials (for example its own certificate), not one shared password across the fleet. The European consumer IoT standard ETSI EN 303 645 makes "no universal default passwords" its very first rule. It's a sensible floor for industrial devices too.
10. Where is our data stored, and can you meet Indian logging and privacy rules? CERT-In's 2022 directions require organisations to report cyber incidents within 6 hours and keep ICT system logs for a rolling 180 days within India. The DPDP Rules 2025 are being phased in over 18 months. Your vendor should be able to say which cloud region holds your data, how long logs are kept, and who can access them.
11. Do your radio devices have Indian type approval? Wireless devices sold in India need equipment type approval (ETA) from the Wireless Planning and Coordination (WPC) wing, including low-power devices in the licence-exempt 865–868 MHz band. Ask to see the approval for each device model. Without it, you inherit the compliance problem.
D. Commercials and ownership
12. Who owns the source code, the firmware and the data? Get this in the contract. At minimum you should own your data and be able to export it in an open format. For custom work, agree source code ownership or escrow.
13. What will it cost to run each device every month after go-live? The build cost is only part of it. Ask for a per-device monthly figure that includes SIM or network fees, cloud hosting, storage, software licences and support. Compare vendors on total cost over three years, not on the first invoice.
14. What does the pilot include, and what counts as success? A good pilot has a fixed scope (a few machines or one line), a fixed duration, a measured "before" baseline and written success criteria that both sides sign. (See how to run a 90-day industrial IoT pilot.)
E. The long term
15. What happens after go-live, and what happens if we part ways? Ask for the support model (response times, who you call, what's included), how many years they'll support the hardware, and an exit plan: documentation, data export, and handover of device credentials.
Red flags
| You hear | Why it's a problem |
|---|---|
| "Our platform does everything, no need to see your plant" | Every plant is different. No site survey means surprises later |
| "We'll replace your PLCs with ours" | Expensive, risky, and usually unnecessary |
| "All devices share one admin password for easy support" | One leaked password exposes the whole fleet |
| "Firmware updates? Our technician visits" | Slow, expensive, and updates won't happen |
| "Missing readings are filled automatically" | Your reports will contain numbers nobody measured |
| "Pricing depends" (with no breakdown) | You can't compare, and costs grow after you sign |
| No answer on who owns the data | You may not be able to leave |
A simple scoring sheet
Score each vendor from 1 to 5 on each area, then multiply by the weight. Change the weights to match your priorities.
| Area | Questions | Weight | Vendor A | Vendor B | Vendor C |
|---|---|---|---|---|---|
| Proof | 1–3 | 25% | |||
| Engineering depth | 4–8 | 30% | |||
| Security and compliance | 9–11 | 20% | |||
| Commercials and ownership | 12–14 | 15% | |||
| Long-term support | 15 | 10% | |||
| Weighted total | 100% |
How Barquecon answers these questions
We'd rather you test us than trust us, so here's where to check:
- Live systems: our Labs page links to browser demos you can run yourself, for factories, buildings, energy, logistics and healthcare.
- Engineering notes: we publish how our platform works, for example how we decode Modbus data from existing PLCs and meters and how an IoT alert becomes an ERP work order.
- How we run projects: see how we work and our engagement models.
- Testing: our QA practice covers IoT device testing as well as software.
Frequently asked questions
How long should IoT vendor selection take?
For a mid-size project, plan on 4–8 weeks: two weeks to shortlist, two to three weeks for demos and written answers, and a site visit by the top two vendors. Skipping the site visit saves time now and costs more later.
Should we choose a hardware company or a software company?
Choose the team that can own the whole chain, from the device to the dashboard to your ERP, even if they partner for some parts. The gaps between a hardware vendor and a software vendor are where projects stall.
Fixed price or time-and-materials for IoT?
A fixed price works for a well-defined pilot. For the rollout, a fixed price per device installed plus a monthly running fee is easier to budget than open-ended time-and-materials. Discovery and integration work often suits time-and-materials.
Do we really need a pilot?
Yes, unless the vendor has already deployed the same solution on the same kind of machines. A pilot proves the data is reliable in your conditions before you commit to the full cost.
Can we use sensors we already have?
Often, yes. Energy meters, PLCs and drives frequently expose their readings over Modbus. A good vendor will check what you already have before proposing new hardware.
Shortlisting IoT partners? Send us your questions and we'll answer all 15 in writing, then show you a live system. Talk to our IoT engineers →